Operating Instructions
Key Adapter CKS2-K-BP/BR-CC-FLX
28
(translation of the original operating instructions) MAN20001512-01-03/22
12.3. Electrical function test
WARNING
Danger of fatal injury as a result of faults in installation and functional check.
Ì
Before carrying out the functional check, make sure that there are no persons in the danger zone.
Ì
Observe the valid accident prevention regulations.
After installation and any fault, the safety function must be fully checked. Proceed as follows:
1. Switch on operating voltage.
¨
The machine must not start automatically.
¨
The key adapter carries out a self-test. The LED then flashes green slowly.
2. Insert key.
¨
The LED illuminates green.
3. Enable operation in the control system.
4. Remove key.
¨
The machine must switch off and it must not be possible to start it as long as a key is not inserted.
¨
The LED flashes green slowly.
Repeat steps 2 … 4 for each key adapter.
13. Factory reset
A factory reset deletes the configuration and restores the device’s factory settings.
To perform a factory reset, connect the two outputs FO1A and FO1B to 0 V before switching on or send the command Ox1E
via IO-Link communication (see chapter
11.3.2. Acyclical data (device data and events) on page 25)
.