Operating Instructions
Key Adapter CKS2-K-BP/BR-CC-FLX
10
(translation of the original operating instructions) MAN20001512-01-03/22
7. Mounting
NOTICE
Risk of damage to equipment and malfunctions as a result of incorrect installation.
Ì
To achieve the degree of protection IP65/IP67, it is necessary to install the key adapter in a clean, flat
metal plate at least 2 mm thick and to tighten the screws with a tightening torque of 0.25 ... 0.35 Nm.
Ì
The device may be damaged if the tightening torque exceeds 0.35 Nm.
Ì
Suitable strain relief must be provided to prevent damage to the connecting cables.
The key adapter is intended for mounting in control panels with a mounting cut-out measuring 33 x 68 mm according to
DIN IEC 61554. The device is fastened using screw clamp elements on the rear side of the panel.
Important!
A pushbutton on the rear of the key adapter is used for the teach-in operation, see chapter
Teaching-in a new key on page 27
. When mounting, ensure that the pushbutton is accessible for
additional teach-in operations after the initial setup.
1. Insert the key adapter, with seal already bonded in place, into the mounting cut-out on the front.
2. Insert the supplied screw clamp elements as far as they will go into the housing cut-outs.
3. Tighten the screws with a tightening torque of 0.25 … 0.35 Nm.
4. After mounting, check the key adapter for firm seating and correct sealing on the front panel.