11-4 Disassembly of crankcase
Remove the cam chain setting plate, and then
remove cam chain.
Loosen the pivot bolt and remove the tensioner.
Loosen 2 bolts on the right crankcase.
Loosen 11 bolts on the left crankcase.
Place right crankcase downward and left
crankcase up.
Tap the left crankcase with a plastic hammer to
remove it.
Caution
Care should be taken not to damage the contact
surfaces.
11 bolts
Cam chain setting plate
Tensioner
2 bolts
Summary of Contents for VECTOR 250 - SERVICE