For Support Contact +46 8 25 28 75, [email protected] or +61 2 9956 7377, [email protected]
External Connector
– ETM DeltaBlack #71610
Seven
I/O’s including a relay is available through the terminal blocks.
Pin allocations are as shown below. The configuration to set the channel function is done in
the configuration
tool described on page 15 “Configuration tool”.
PIN
CONFIGURABLE FUNCTIONS
TERMINAL BLOCK
CH1
•
Digital Input: LL<0.5V, HL>2.5V, Max Input 50VDC
•
Digital Output: LL0V, HL3V, 0.1mA
•
Pulse Input: LL<0.5V, HL>2.5V, Max Input 50VDC
CH2
•
Digital Input: LL<0.5V, HL>2.5V, Max Input 50VDC
•
Digital Output: LL0V, HL3V, 0.1mA
•
Pulse Input: LL<0.5V, HL>2.5V, Max Input 50VDC
•
Analogue Input: 0-2.5V, Max Input 50VDC
CH3
•
Digital Input: LL<0.5V, HL>2.5V, Max Input 50VDC
•
Digital Output: LL0V, HL3V, 0.1mA
•
Pulse Input: LL<0.5V, HL>2.5V, Max Input 50VDC
•
Analogue Input: 0-2.5V, Max Input 50VDC
CH4
•
Digital Input: LL<0.5V, HL>2.5V, Max Input 50VDC
•
Digital Output: LL0V, HL3V, 0.1mA
•
Pulse Input: LL<0.5V, HL>2.5V, Max Input 50VDC
•
Analogue Input: 0-2.5V, Max Input 50VDC
CH5
•
Analogue Input: 0-5V, Max Input 50VDC
CH6
•
Analogue Input: 0-10V, Max Input 50VDC
CH7
•
Digital Input: LL<0.5V, HL>2.5V, Max Input 50VDC
•
Digital Output: LL0V, HL3V, 0.1mA
•
Analogue Input: 0-2.5V, Max Input 50VDC
Relay
•
COM (Common)
•
NO (Normally Open)
•
NC (Normally Closed)
Sensor Feed
•
5V and 16V max 100mA
Note that sensor feed is not always ON, this is
configured in the Configuration tool.
CAUTION
Take care to ensure
that only the correct
connectors are used or
mechanical damage to