For Support Contact +46 8 25 28 75, [email protected] or +61 2 9956 7377, [email protected]
CHANNELS TAB
This section has settings for the I/O channels and the corresponding alarms.
For channels 1, we have the following options:
Open
→
Close(N.O) Alarm Message
This message will be sent when a circuit involving the actual I/O pin changes from open to
closed (from not connected to grounded). The I/O is indicating high signal when not
connected, pull upped. See later in this document for examples.
Close
→
Open(N.C) Alarm Message
This message will be sent when a circuit involving the actual I/O pin changes from close to
open (from grounded to not connected). The I/O is indicating high signal when not
connected, pull upped. See later in this document for examples.
Digital I/O alarm
Set which type of change that will trigger an alarm. The I/O is indicating high signal when not
connected, pull upped. See later in this document for examples.
Port
Set the I/O to input or output. In the case of output, set the initial state to ON or OFF.
SMS Phone Number
This setting is used to specify which, if any, phone numbers to use for sending SMS alarms
related to this input.
Note: Never tick a blank number as this will cause the wireless mode to try to repeatedly
send an alarm to a non-existent number.