3
Programming
24
About Menu
When there is no architectural configuration file loaded into the Paradigm ACP, certain
menu lists are not available for viewing or use. For instance, without an architectural
configuration file there will be no DMX level data, project information, or system network
information to view.
About Dimmer
Use the touch wheel to scroll to a different dimmer or use the alpha-numeric button pad to
specify a dimmer number. Dimmer data updates when a new dimmer is selected. Push
enter (
) to view additional details about your selected dimmer.
To exit the “About Dimmer menu and return to the previous menu press the back
button ( ).
DMX Level Data
When a streaming sACN (sACN) patch exists for local DMX ports, additional patch
information is displayed beneath each port. For DMX inputs this patch information pertains
to sACN output, and for DMX outputs this patch information pertains to sACN input.
•
When a streaming sACN patch is shown as “Universe/1st used address”. This indicates
a 1-to-1 patch between the DMX port and the sACN universe for all 512 addresses.
•
The "
" character is shown when a port has a sACN patch but is not a 1-to-1 patch. In
this instance, the first sACN universe /address used for that port is listed for the lowest
address of that sACN universe.
N o t e :
The “About Menu” is provided for you to view information only. There are no
editing tools or menu lists available.
1 About Dimmer
2 DMX Level Data
3 Version Info
4 Project Information
5 Statistics
6 View Message Log
7 System Network
About
8 Stations & LonWorks
The “About Menu” provides you direct access to view
details about your dimmers (when the Paradigm ACP is
installed in a host DRd rack), current DMX level data,
software version information, project information,
statistics, message log, system network, and stations
and LonWorks.
About Dimmer
1
DMX Channel:
125
Module Type:
D20F
Mode:
Fluorescent
Current Level:
100%
Source:
DMX
Input
< p u s h E n t e r f o r m o r e >
The “About Dimmer” menu displays only when the Paradigm
ACP is installed in a host DRd rack. By default, the “About
Dimmer” menu automatically selects and displays the data for
the first dimmer in the rack. Notice the title bar displays the
selected dimmer number.
DMX Level Data
Port A:
Input
1/1
Active
Port B:
Output
≈2/1
Active
The “About DMX Level Data” menu displays the available DMX
input and DMX output port and its current status of active,
inactive, or disabled. Status is updated once every 500ms.
When a DMX port is disabled, there is no data to display. DMX
output ports are only inactive when there are no patched
addresses.