2
Paradigm ACP Basic Navigation
18
•
internal operating temperature
- The internal operating temperature is measured and
displays on the dimming rack status display. By default, temperature is displayed in °F
when the rack is 120, 240, or 277 VAC, and in °C when the rack is 230 VAC.
•
rack software version
- The rack software is specific to the dimming engine and may
differ from the ACP software version.
Arch Control Status Display
display title
- A menu’s title appears in the first row of every display for easy navigation.
scroll to previous display
- When the counter-clockwise symbol appears in the display
use the touch wheel to scroll counter-clockwise for the Dimming Rack Status display.
processor name
- Prior to using configuration data with a Paradigm processor in a multi-
processor system, each processor must be configured as one of the 20 possible per
See “Set Processor Identity and IP Address” on page 9.
processor IP address
- In addition to assigning a processor name (id) the processor IP
address must also be assigned. Automatic IP address settings are used when the
processor name (identity) is unknown.
status message area
- Status messages are common to both the dimming rack and ACP
status displays. When a system error is detected, the message changes to reflect the
specific error type. When multiple errors are detected, each error message cycles on the
display, first by severity and then by chronological occurrence. Reference
for a complete listing of possible errors and the actions required to clear them.
DMX A:
Indicates DMX port configuration and activity.
DMX B:
Indicates DMX port configuration and activity. When the Paradigm ACP is installed
in a host DRd enclosure, port B must be configured as an output and is always active.
rack type
- Displays the host rack type. The Paradigm ACP automatically detects the rack
type as either an ERn, DRd6, DRd12, or DRd12AX12X.
software version
- The ACP software is specific to the Paradigm architectural control
processor and may differ in version number from the dimming engine software version.
Arch Control Status
Processor Name
IP: 10.101.10.101
System OK
DMX A:
In
Inactive
DMX B:
Out
Active
DRd12
v1.4.5