51
Paradigm Architectural Control Processor Configuration Manual
Dimmer Check
The “Dimmer Check” menu provides a quick and easy method to step through all your
individual dimmers. This is useful for checking lamps or checking focus. Only one dimmer
number is illuminated at a time.
Step 1:
Use the touch wheel to scroll to “Dimmer Check” from within the “Dimming
Control” menu and press enter (
). The Dimmer Check menu displays.
Step 2:
Choose which navigation method you would like to use to initiate the dimmer
check.
Scroll to “Next Dimmer” or “Previous Dimmer” and press enter (
).
•
Each press of enter (
), when using “Next Dimmer” or “Previous Dimmer”,
increments to either the next dimmer in the list or the previous dimmer in the
list. When using this method the dimmer list rolls-over continuously from the
last dimmer in the list to the first dimmer in the list.
Select the dimmer value field (dimmer 1 in the example graphic above).
a: Press enter (
) to change the focus from “Dimmer Number” to the dimmer
number value.
b: Use the touch wheel to scroll through the dimmer list. When using this
method, the dimmer list does not roll-over from the last dimmer in the list to
the first dimmer in the list.
c: Use the touch wheel’s increment
or
decrement
buttons
to
step through the dimmer list. When using this method, the dimmer list does
not roll-over from the last dimmer in the list to the first dimmer in the list.
d: Specify the dimmer number using the alpha-numeric button pad.
Release Set Levels
N o t e :
Dimmers that are controlled from the “Set Levels” action cannot be controlled from
the architectural system, DMX, or sACN until they have been released.
Dimmer Check
Dimmer Number:
1
Level:
80
Next Dimmer:
Previous Dimmer
current dimmer
in check
level that the dimmer will
illuminate to. Can be set to
any value 0 - 100.
scroll to “Next Dimmer” and
press enter
to step
through the dimmer list.
scroll to “Previous Dimmer”
and press
to step back
through the dimmer list.
Release Set Levels
All Set Levels
control has been
Released.
When “Release Set Levels” is selected all levels that had been
set by the “Dimming Control” menu are released.
This message screen is displayed for only one second, then