ETC Installation Guide

ColorSource PAR v1.7

Installation

Emergency Lighting Considerations

Luminaires that are used in emergency lighting applications must provide a
minimum illumination level over the identified means of egress path in
accordance with the Life Safety Code

®

, NFPA 101. A luminaire that is intended

to serve this purpose must be mounted at a height where it will not readily be
subjected to tampering by unauthorized personnel and where the minimum
required illumination level over the egress path can be achieved. The ETC
DMX Emergency Bypass Controller that is driving the luminaire upon loss of
utility power must be programmed to drive the ColorSource PAR to full
illumination.

Mounting

The ColorSource PAR ships with a standard yoke for mounting with a clamp.
An expandable floor stand yoke is available as an optional accessory. Contact
your local dealer for more information.

Safety cable 
attachment 
loop

Safety Cable

A safety cable (or other approved safety device)
must be attached to the fixture. Attachment
loops are on the rear of the fixture. Take care to
leave as little slack as possible in the safety cable
to avoid catching the yoke of the fixture.

Connectors

Power: Two powerCON

®

connectors for power in and thru

Data (DMX512/RDM): Two five-pin XLR connectors OR two
RJ45 connectors for data in and thru

Conversion cables are available from ETC. Please contact your ETC customer
service representative and request part number W6538 for RJ45 to female
XLR or part number W6539 for RJ45 to male XLR.

Note:

This fixture is not Ethernet/data network compatible.

Note:

The ColorSource PAR is not self terminating. You must

terminate the last fixture in line with a 120 Ohm resistor. To purchase
a terminator, please contact ETC customer service and request part
number N4086 (RJ45 terminator) or SGE1507 (XLR terminator).

ColorSource PAR

Page 5 of 12

ETC

Summary of Contents for ColorSource PAR

Page 1: ...e ColorSource PAR is an affordable LED fixture that uses the RGB L red green blue and lime color system to provide a rich bright light The ColorSource PAR is available in both original and Deep Blue v...

Page 2: ...The ColorSourcePAR is a Directly Controlled Luminaire suitable for use in emergency lighting applications in accordance with 2017 National Electrical Code section 700 24 when used with an ETC DMX Emer...

Page 3: ...INSTRUCTIONS The luminaire must be installed at least 0 1 m 4 0 in away from all lighted objects Le luminaire doit tre install au moins 0 1 m 4 0 po de tout objet clair Do not mount the fixture on or...

Page 4: ...eved at 25 C 77 F 41 C 106 F Electrical Operates between 100 V and 240 VAC at a frequency of 50 60 Hz Maximum power consumption is 120 W Up to 9 luminaires 15 A max may be linked via power thru connec...

Page 5: ...ptional accessory Contact your local dealer for more information Safety cable attachment loop Safety Cable A safety cable or other approved safety device must be attached to the fixture Attachment loo...

Page 6: ...ord into the power source Power thru Power in Data in Data thru Mode Up and Down User interface Power Up Press any button to wake the display The display shows the DMX address See Set the DMX Address...

Page 7: ...and hold the Mode button for 3 seconds The display shows the current DMX control mode 3 Press the Up button or Down button to change the DMX control mode 5ch 5 channel mode intensity red green blue an...

Page 8: ...s and Sequences The fixture has twelve factory configured presets and five factory configured sequences When you play a preset or sequence on a fixture The same preset number or sequence number plays...

Page 9: ...ton to access the Presets Sequences menu 3 Press the Up button or Down button to navigate to the preset number that you want to re record 4 Press and hold the Mode button for 3 seconds to confirm the...

Page 10: ...reset in real time 5 Press the Mode button to confirm your selection and return to the Presets Sequences menu The display will automatically return to the Presets Sequences menu after 10 seconds of in...

Page 11: ...nnected fixture only on ColorSource fixtures running software v1 3 0 or newer Use UpdaterAtor to update individual fixtures running versions older than v1 3 0 Note If you have other types of fixtures...

Page 12: ...een OtP and Err to indicate that the fixture has gone into over temperature protection mode to avoid damaging the fixture Once the fixture has self cooled the error will automatically clear No App Scr...

Reviews: