background image

ETC Installation Guide

ColorSource PAR v1.7

DMX Control Channels

DMX 

Channel

5ch

(5 channel)

dir

(Direct)

1ch

(1 Channel)

rgb

(RGB)

1

Intensity

Intensity

Intensity

Red

2

Red

Red

Green

3

Green

Green

Blue

4

Blue

Blue/Indigo*

5

Strobe**

Lime

6

Strobe**

*Original ColorSource PAR fixture uses blue in channel 4; Deep Blue fixture uses indigo in

channel 4.

**Use DMX values of 0 or 255 for no strobe. Use values of 1–254 to increase the strobe rate

from 1 per second up to 33 per second.

Data Loss Behavior

When DMX data is lost, the fixture does one of the following actions: 

If you selected a preset or sequence, that preset or sequence
automatically plays.

If no preset or sequence is active in the background, the fixture goes
dark and the DMX start address flashes on the user interface.

Play Presets and Sequences

The fixture has twelve factory-configured presets and five factory-configured
sequences. When you play a preset or sequence on a fixture:

The same preset number or sequence number plays on any connected
fixtures that are not receiving DMX.

If you power down the fixture, the preset or sequence resumes when
you power it on again.

You can re-record presets and sequences through an RDM device or manually
on the fixture. See

Re-record Presets on the facing page

.

1. Press the Mode button to activate the Presets/Sequences menu. The

last active preset or sequence plays automatically. (If DMX data is
present, the current preset or sequence plays in the background and
DMX data continues to take priority.)

2. Press the Up button or Down button as needed to scroll through the

available presets and sequences.

3. To stop the selected preset or sequence, press the Mode button a

second time. The display will revert to show the DMX start address.

ColorSource PAR

Page 8 of 12

ETC

Summary of Contents for ColorSource PAR

Page 1: ...e ColorSource PAR is an affordable LED fixture that uses the RGB L red green blue and lime color system to provide a rich bright light The ColorSource PAR is available in both original and Deep Blue v...

Page 2: ...The ColorSourcePAR is a Directly Controlled Luminaire suitable for use in emergency lighting applications in accordance with 2017 National Electrical Code section 700 24 when used with an ETC DMX Emer...

Page 3: ...INSTRUCTIONS The luminaire must be installed at least 0 1 m 4 0 in away from all lighted objects Le luminaire doit tre install au moins 0 1 m 4 0 po de tout objet clair Do not mount the fixture on or...

Page 4: ...eved at 25 C 77 F 41 C 106 F Electrical Operates between 100 V and 240 VAC at a frequency of 50 60 Hz Maximum power consumption is 120 W Up to 9 luminaires 15 A max may be linked via power thru connec...

Page 5: ...ptional accessory Contact your local dealer for more information Safety cable attachment loop Safety Cable A safety cable or other approved safety device must be attached to the fixture Attachment loo...

Page 6: ...ord into the power source Power thru Power in Data in Data thru Mode Up and Down User interface Power Up Press any button to wake the display The display shows the DMX address See Set the DMX Address...

Page 7: ...and hold the Mode button for 3 seconds The display shows the current DMX control mode 3 Press the Up button or Down button to change the DMX control mode 5ch 5 channel mode intensity red green blue an...

Page 8: ...s and Sequences The fixture has twelve factory configured presets and five factory configured sequences When you play a preset or sequence on a fixture The same preset number or sequence number plays...

Page 9: ...ton to access the Presets Sequences menu 3 Press the Up button or Down button to navigate to the preset number that you want to re record 4 Press and hold the Mode button for 3 seconds to confirm the...

Page 10: ...reset in real time 5 Press the Mode button to confirm your selection and return to the Presets Sequences menu The display will automatically return to the Presets Sequences menu after 10 seconds of in...

Page 11: ...nnected fixture only on ColorSource fixtures running software v1 3 0 or newer Use UpdaterAtor to update individual fixtures running versions older than v1 3 0 Note If you have other types of fixtures...

Page 12: ...een OtP and Err to indicate that the fixture has gone into over temperature protection mode to avoid damaging the fixture Once the fixture has self cooled the error will automatically clear No App Scr...