ETC Installation Guide
ColorSource PAR v1.7
Environment
The ColorSource PAR operates in ambient temperatures of 0°C–40°C and
comes with a variable-speed fan. The ColorSource PAR is for indoor use only.
•
Maximum recommended ambient operating temperature: Ta = 40°C
(104°F)
•
Maximum anticipated external surface temperature at 40°C ambient:
Tmax = 80°C (176°F)
•
External temperatures after 5 minutes of full-brightness operation at
25°C (77°F) ambient: 30°C (86°F)
•
External Temperature (steady state achieved) at 25°C (77°F): 41°C
(106°F)
Electrical
•
Operates between 100 V and 240 VAC at a frequency of 50/60 Hz.
•
Maximum power consumption is 120 W.
•
Up to 9 luminaires (15 A max) may be linked via power thru connector
(10 luminaires total per circuit) when used with an R20 Relay Module
or Unison Echo Relay Panel. Consult breaker trip curves when used
with other equipment. Requires power from a non-dimmable source.
•
Inrush:
-
120 V: 35 A (first half-cycle)
-
240 V: 49 A (first half-cycle)
Typical Power Consumption
100 V
120 V
230 V
Power
Current
Power
Current
Power
Current
Idle
1.22 W
0.03 A
1.21 W
0.03 A
1.14 W
0.03 A
Direct at Full
107 W
1.07 A
106 W
0.88 A
104 W
0.46 A
ColorSource PAR
Page 4 of 12
ETC