background image

ETC Installation Guide

ColorSource PAR v1.7

Adjust the Intensity of Presets

1. Ensure that DMX data is not present.
2. Press the Mode button to access the Presets/Sequences menu, and

then press the Up button or Down button to select the preset that you
want to edit.

3. Press and hold the Mode button for 3 seconds. The display shows

L:

followed by either an intensity level from

0

99

or

FL

for full.

4. Press the Up button or Down button to change the intensity level of

the preset in real time.

5. Press the Mode button to confirm your selection and return to

the Presets/Sequences menu.

The display will automatically return to the Presets/Sequences menu after
10 seconds of inactivity, and edits to the preset intensity will not be saved.

Lock the User Interface

After you have set up the fixture, you can lock the user interface to prevent
additional changes.

1. Press and hold the Up button and Down button simultaneously for

3 seconds. The display will show

Loc

to indicate that the user interface

is locked.

2. To unlock the user interface, press and hold the Up button and Down

button simultaneously for 3 seconds.

ColorSource PAR

Page 10 of 12

ETC

Summary of Contents for ColorSource PAR

Page 1: ...e ColorSource PAR is an affordable LED fixture that uses the RGB L red green blue and lime color system to provide a rich bright light The ColorSource PAR is available in both original and Deep Blue v...

Page 2: ...The ColorSourcePAR is a Directly Controlled Luminaire suitable for use in emergency lighting applications in accordance with 2017 National Electrical Code section 700 24 when used with an ETC DMX Emer...

Page 3: ...INSTRUCTIONS The luminaire must be installed at least 0 1 m 4 0 in away from all lighted objects Le luminaire doit tre install au moins 0 1 m 4 0 po de tout objet clair Do not mount the fixture on or...

Page 4: ...eved at 25 C 77 F 41 C 106 F Electrical Operates between 100 V and 240 VAC at a frequency of 50 60 Hz Maximum power consumption is 120 W Up to 9 luminaires 15 A max may be linked via power thru connec...

Page 5: ...ptional accessory Contact your local dealer for more information Safety cable attachment loop Safety Cable A safety cable or other approved safety device must be attached to the fixture Attachment loo...

Page 6: ...ord into the power source Power thru Power in Data in Data thru Mode Up and Down User interface Power Up Press any button to wake the display The display shows the DMX address See Set the DMX Address...

Page 7: ...and hold the Mode button for 3 seconds The display shows the current DMX control mode 3 Press the Up button or Down button to change the DMX control mode 5ch 5 channel mode intensity red green blue an...

Page 8: ...s and Sequences The fixture has twelve factory configured presets and five factory configured sequences When you play a preset or sequence on a fixture The same preset number or sequence number plays...

Page 9: ...ton to access the Presets Sequences menu 3 Press the Up button or Down button to navigate to the preset number that you want to re record 4 Press and hold the Mode button for 3 seconds to confirm the...

Page 10: ...reset in real time 5 Press the Mode button to confirm your selection and return to the Presets Sequences menu The display will automatically return to the Presets Sequences menu after 10 seconds of in...

Page 11: ...nnected fixture only on ColorSource fixtures running software v1 3 0 or newer Use UpdaterAtor to update individual fixtures running versions older than v1 3 0 Note If you have other types of fixtures...

Page 12: ...een OtP and Err to indicate that the fixture has gone into over temperature protection mode to avoid damaging the fixture Once the fixture has self cooled the error will automatically clear No App Scr...

Reviews: