ETC Installation Guide

ColorSource PAR v1.7

Restore Factory Defaults

Press and hold the Mode button, Up button, and Down button
simultaneously for 5 seconds. The DMX start address will blink once to
confirm that defaults have been restored.

Error Codes

There are three error codes that may be shown on the user interface.

CAL

: Screen toggles between

CAL

and

Err

to indicate a problem with

the color calibration. The fixture will need to be returned to the ETC
factory; contact your local dealer to set up a repair.

OtP

: Screen toggles between

OtP

and

Err

to indicate that the fixture

has gone into over-temperature protection mode to avoid damaging
the fixture. Once the fixture has self-cooled, the error will automatically
clear.

No App

: Screen toggles between

no

and

APP

to indicate that the

upgraded fixtures have a software issue. Reload software to clear the
error. If the error persists, contact ETC.

RDM Values

Parameter

Fixture

Value

Description

Manufacturer ID

All

0x6574

Electronic Theatre

Controls

Model ID

ColorSource PAR

0x0201

ColorSource PAR

Deep Blue

0x0202

DMX Start Address All

0x00F0

Range = 1–512

DMX Personality

All

0x00E0

1 = 5 Channel

2 = Direct

3 = 1 Channel

4 = RGB

Output Frequency

All

0x8123

0 = Standard (1.2 kHz)

1 = High (25 kHz)

ColorSource PAR

Page 12 of 12

ETC

Summary of Contents for ColorSource PAR

Page 1: ...e ColorSource PAR is an affordable LED fixture that uses the RGB L red green blue and lime color system to provide a rich bright light The ColorSource PAR is available in both original and Deep Blue v...

Page 2: ...The ColorSourcePAR is a Directly Controlled Luminaire suitable for use in emergency lighting applications in accordance with 2017 National Electrical Code section 700 24 when used with an ETC DMX Emer...

Page 3: ...INSTRUCTIONS The luminaire must be installed at least 0 1 m 4 0 in away from all lighted objects Le luminaire doit tre install au moins 0 1 m 4 0 po de tout objet clair Do not mount the fixture on or...

Page 4: ...eved at 25 C 77 F 41 C 106 F Electrical Operates between 100 V and 240 VAC at a frequency of 50 60 Hz Maximum power consumption is 120 W Up to 9 luminaires 15 A max may be linked via power thru connec...

Page 5: ...ptional accessory Contact your local dealer for more information Safety cable attachment loop Safety Cable A safety cable or other approved safety device must be attached to the fixture Attachment loo...

Page 6: ...ord into the power source Power thru Power in Data in Data thru Mode Up and Down User interface Power Up Press any button to wake the display The display shows the DMX address See Set the DMX Address...

Page 7: ...and hold the Mode button for 3 seconds The display shows the current DMX control mode 3 Press the Up button or Down button to change the DMX control mode 5ch 5 channel mode intensity red green blue an...

Page 8: ...s and Sequences The fixture has twelve factory configured presets and five factory configured sequences When you play a preset or sequence on a fixture The same preset number or sequence number plays...

Page 9: ...ton to access the Presets Sequences menu 3 Press the Up button or Down button to navigate to the preset number that you want to re record 4 Press and hold the Mode button for 3 seconds to confirm the...

Page 10: ...reset in real time 5 Press the Mode button to confirm your selection and return to the Presets Sequences menu The display will automatically return to the Presets Sequences menu after 10 seconds of in...

Page 11: ...nnected fixture only on ColorSource fixtures running software v1 3 0 or newer Use UpdaterAtor to update individual fixtures running versions older than v1 3 0 Note If you have other types of fixtures...

Page 12: ...een OtP and Err to indicate that the fixture has gone into over temperature protection mode to avoid damaging the fixture Once the fixture has self cooled the error will automatically clear No App Scr...

Reviews: