ETAS
Technical Data
FETK-S2.1 - User’s Guide
35
7.2.2
Measurement Data Memory
7.3
FETK Ethernet Interface
7.4
Environmental Conditions
Item
Characteristics
Location
Typically located within the emulation
memory when using DISTAB17
hooks. Measurement data memory
can be located in internal RAM if the
entire ED RAM is needed for calibra-
tion.
Update
Logic devices updated using HSP
software
Item
Characteristics
Connection
1 Gbit/s Ethernet
Cable length
max. 30 m / 100 ft
Ethernet Interface
DC decoupling
NOTE
The FETK Ethernet interface utilizes a proprietary Ethernet protocol and is
compatible only with the Gigabit Ethernet interfaces of the ES89x ECU Inter-
face Module.
Item
Characteristics
Temperature range (operation)
- 40 °C to +110 °C/ - 40 °F to +230 °F
Temperature range (storage)
0 °C to +50 °C/ - 18 °F to +122 °F
Relative humidity (non-condensing)
0 to 95%
Operating altitude
max. 5000 m/ 16400 ft
Contamination level
2
Degree of protection
Determined by installation in ECU