8
www.eta.co.at
Maintenance table
Cleaning and maintenance
2.2
Maintenance table
Tasks
Regular
ly
Every
3,000 h
or once
a year
Every
6,000 h
or
every
2 years
to be done by
Check fill level of ash bins
X
X
X
Customer
Check heating system's water pressure
X
X
X
Customer
Check air intake in installation room
X
X
Customer
Clean flue tube
X
X
Customer
Clean combustion chamber
X
X
Customer
Check lining of the combustion chamber
X
X
Customer
Check the firebed switch
X
X
Customer
Visual check of the stoker screw
X
X
Customer
Clean ignition fan and openings
X
X
Customer
Check protective elements and grate elements
X
X
Customer
Visual check of the ash cross screw
X
X
Customer
Check grate ash screw
X
X
Customer
Clean roller guide of the moving grate
X
X
Customer
Remove ash from the reversing chamber
X
X
Customer
Check turbulators
X
X
Customer
Clean flue gas recirculation ducts
X
X
Customer/expert
Clean the heat exchanger
X
X
Customer/expert
Clean connection pipe to draught fan
X
X
Customer/expert
Visual check of the heat exchanger screw
X
X
Customer/expert
Clean flue gas temperature sensor
X
X
Customer/expert
Clean flue gas recirculation piping, check flue gas recirculation
flap
X
X
Customer/expert
Clean draught fan of the flue gas recirculation
X
X
Customer/expert
Lubricate heat exchanger cleaner drive
X
X
Customer/expert
Check stoker drive chain
X
X
Customer/expert
Check the seal of the ash bin or the transfer coupling
X
X
Customer/expert
Check heat exchanger ash screw
X
X
Customer/expert
Clean the lambda probe
X
X
Customer/expert
Visually check safety valves
X
X
Customer/expert
Visually check thermal relief valves
X
X
Customer/expert
Check operational readiness of safety devices in fuel path
X
X
Customer/expert
Clean the upper area of the heat exchanger
X
Expert
Clean draught fan
X
Expert
Check seal on heat exchanger cover
X
Expert
Check safety switch of the discharge
X
Expert
Check rotary valve stop
X
Expert
Check silicon hoses for differential pressure switch and
transmitter
X
Expert
Check air valve
X
Expert
Check automatic closing of the actuators
X
Expert