Fuel store
Technical data
71
Deviations from these specifications are only possible in consultation with ETA Heiztechnik GmbH.
Discharge
Unit
BG 1
BG 2
BG 2.5
BG 3
Trough - width B
mm
140
190
230
Ball joint - diameter K
mm
200
250
compatible boilers:
eHACK
kW
20 - 80
100 - 170 180 - 240
HACK VR
kW
-
-
250
333 - 350
500
Agitator for wood chips
Discharge
Unit
BG 1
BG 2
BG 2.5
BG 3
Floor agitator - Diameter D and drive power:
with leaf spring arm
m
1.5 - 4
3 - 4
kW
0.37
0.55
1.1
1.5
with articulated arm
m
4.5 - 5
kW
0.55
1.1
1.5
with double articulated arm
m
5.5 - 6
kW
0.55
1.1
1.5
closed trough:
Total length L
1
m
< 6
Inclination α
< 15°
Fill height H
m
< 5
Number of spring arms
2