Installation
Temperature sensors
51
The position of the temperature sensor for the column
as well as the safety temperature limiter of the
combustion chamber must be checked. They must be
completely inserted in the immersion sleeves in order
to measure the correct temperature.
Fig. 9-53: Immersion sleeve for the column
Check the position of ash duct temperature sensor
This temperature sensors has already been
installed at the factory.
Check the position of ash duct temperature sensor It
must be completely inserted in the immersion sleeve in
order for it to measure the correct temperature.
Fig. 9-54: Ash duct temperature sensor
Installing the flow and return temperature sensors
Insert the temperature sensor for the flow into the
immersion sleeve on the heat exchanger and secure
with the brackets already installed.
Fig. 9-55: Immersion sleeve for the flow temperature sensor
and safety temperature limiter
This immersion sleeve for the flow temperature
sensor contains the pre-installed temperature
sensor of the heat exchanger safety temperature
limiter. It must be completely inserted in the immersion
sleeve in order for it to measure the correct tempera-
ture.
Fig. 9-56: Immersion sleeve for return temperature sensor