56
www.eta.co.at
External ash removal
Installation
Remove the connection unit again, place it onto the
ash bin, and secure with the screw cap.
Fig. 9-75: Screw cap
Then use the hose clamps to secure the bellows.
Check whether the connection unit can be
suspended in the upper and lower positions.
Mount the position switch
Mount the position switch on the screw cap. Only
hand-tighten the nut initially.
Fig. 9-76: Position switch
Lock the screw cap on the ash bin. The switch must be
actuated in this position. If not, adjust the switch
position. Once the switch is in the correct position,
carefully tighten the nut.
Fig. 9-77: Check the actuation
Secure the electric cable with a cable tie. This
prevents inadvertent removal of the protective
switch cap, which could otherwise lead to an electric
shock (230 V).
Fig. 9-78: Secure the electrical cable with a cable tie