eSync DVR Manual
Revision A
- 37 -
© 2008 eSync Manual
© eSync
System
Setup
1) Event
1) Motion - This function enables the DVR to record when there is motion on the video channel to trigger
recording. The default value is [Off].
◊
Full
Detects all motion of the image in each channel will trigger recording.
1.
Select
{Event}
{Motion}
for the channel using the arrow keys and press the [Select] button.
2. On the selection window, select All.
◊
Partial
Motion detection in the user-defined areas on the grid only will trigger recording.
1.
Select
{Event}
{Motion}
for the channel using the arrow keys and press the [Select] button.
2. On the selection window, select Partial.
3. The grid will be displayed on the screen.
4. Select the area where motion will be detected using the arrow keys and press the [Select] button.
5. Select the zone and press the [ESC] button.
◊
Off
Motion detection in the video is disabled.
◊
Select the motion detection sensitivity
1.
Select
{Event}
{Motion}
{Sensitivity}
for the channel using the arrow keys and press the Menu
button.
2. On the selection window, select the sensitivity using the arrow keys and press the [Select] button.
To set all channels at the same time, navigate the arrow keys to go to the top of the
{Motion}
on
top of the column and press the [Select] button.
2) Sensor - To set the detection of input triggered by external sensors. Up to 4/8/16 external sensors can be
set. When a signal of an external sensor is detected, the camera channel assigned to the sensor will start
recording.
1.
Select
{Event}
{Sensor}
for the channel using the arrow keys and press the [Select] button.
2. On the selection window, select an external sensor channel using the arrow keys and press the Select
button.
3.
Select
{Event}
{Sensor}
{Sensor Type}
for the channel using the arrow keys and press the Menu
button.
On the selection window, select the sensor type using the arrow keys and press the [Select] button.
To set all channels at the same time, navigate the arrow keys to go to the top of the
{Sensor}
on
top of the column and press the [Select] button.
Normal Close (NC)
: Normally closed; opens when a signal is received
Normal Open (NO)
: Normally open; closes when a signal is received
Summary of Contents for SSA-0424e
Page 1: ......