In inBIO reader connection, if the reader shares the power with the control
panel, it is recommended that the wire
should be less than 100 meters
. If you
need to use in the longer distance, please use the separate power supply.
5.
For this access control operator panel, putting place 8 of the DIP switch to the
ON
position is equivalent to parallel connection of one 120ohm resistance
between the 485+ and 485- lines.
As shown in the figure below, put number 8 of the DIP switches of the first and last
control panels to
ON
position.
RS485 Communication System Networking
4.4 DIP Switch Settings
1. 485 address setting
Number 1-6 of the DIP switch are reserved to set device number for RS485
30
Installation Guide for inBIO
4
60 Series Control Panel