3.7 Relay Output Connection
Note
: The factory default jumping is set as dry mode.
3) Considering of the consumption of the control panel, the Wiegand reader and the
inBIO reader, the standard power supply is 12V/3A. So we don’t recommend the
lock and the control panel use the common power supply. If it is necessary to use,
20
inBIO160 has two relays (by default, one used as a control lock and the other
used as an auxiliary output); inBIO260 has four relays (by default, two used as
control locks and the other two used as auxiliary outputs); inBIO460 has eight
relays (by default, four used as control locks and the other four used as auxiliary
outputs).
The relays for auxiliary outputs may be connected to monitors, alarms, door
bells, etc. Auxiliary outputs are set through relevant access control software. For
details, please refer to
Access5.0 User Manual.
A lock relay can be connected in the dry and wet modes, while an auxiliary
output relay cannot. The following illustrates relay output connection with an
example of door connection.
1) An access control panel provides multiple electronic lock outputs. The COM and
NO terminals are applicable to the locks that are unlocked when power is connected
and locked when power is disconnected (that is NO lock). The COM
and NC terminals are applicable to the locks that are locked when power is
connected and unlocked when power is disconnected (that is NC lock).
2) The control panel supports “dry mode” and “wet mode” by using the jumper. For
“wet mode”, short 2-3 and 4-5 terminals. The control panel and the lock use
the separate power supply. One is connected with +12V and GND of POWER
interface (for the control panel), the other is connected with V+ and V- of
LOCK interface (for the lock)..
Dry mode jumper setting:
Short 1-2 and 3-4, and the device power supply will be
used for the relay output.
Installation Guide for inBIO
4
60 Series Control Panel
Summary of Contents for inBIO460 Series
Page 1: ...Security at Fingertips www esslsecurity com...
Page 2: ......
Page 16: ...3 Connection and Installation inBIO260 terminal connection diagram 13...
Page 17: ...inBIO460 terminal connection diagram 14 Installation Guide for inBIO460 Series Control Panel...
Page 27: ...24 Installation Guide for inBIO460 Series Control Panel...
Page 37: ...between 485 and 485 34 Installation Guide for inBIO460 Series Control Panel...