4. System Networking
communication. The code is binary, and the lower places are in the front. When the
switch is set to ON position, it indicates 1 (on); when the switch is set downwards, it
indicates 0 (off).
For example, to set a device number 39=1+2+4+32, which corresponds to the binary
code 111001, put number 1, 2, 3, and 6 to ON position, as illustrated below.
485 address setting table:
Switch Setting
Place Address
1 2 3 4 5 6
Address No.
1 2 4 8 16 32
01 ON
OFF
OFF
OFF
OFF
OFF
02 OFF
ON
OFF
OFF
OFF
OFF
03 ON
ON
OFF
OFF
OFF
OFF
04 OFF
OFF
ON
OFF
OFF
OFF
05 ON
OFF
ON
OFF
OFF
OFF
06 OFF
ON
ON
OFF
OFF
OFF
07 ON
ON
ON
OFF
OFF
OFF
08 OFF
OFF
OFF
ON
OFF
OFF
09 ON
OFF
OFF
ON
OFF
OFF
10 OFF
ON
OFF
ON
OFF
OFF
11 ON
ON
OFF
ON
OFF
OFF
12 OFF
OFF
ON
ON
OFF
OFF
13 ON
OFF
ON
ON
OFF
OFF
14 OFF
ON
ON
ON
OFF
OFF
15 ON
ON
ON
ON
OFF
OFF
31