3.5 Connection with External Accessories
1. Door sensor
A door sensor is used to detect the open/closed status of a door. With a door sensor
switch, an access control panel can detect illegal opening of a door, and will trigger
an alarm. Moreover, if a door is not closed within a specified period of time after it
is opened, the door control panel will also prompt an alarm. It is recommended to
select two-core wires over 0.22 mm
2
. A door sensor may be omitted if it is unnecessary to
monitor online the open/closed status of a door, trigger an alarm when the door is not
closed for a long time or there is illegal access, and use the interlock function.
2. Exit button
An exit button is a switch installed indoors to open a door. When you press the
button, the door will be opened. An exit button is fixed at a height of about 1.4
meter above the ground. Ensure it is located in the right position without slant, and
its connection is correct and secure (Cut off the exposed end of any unused wire
and wrap it with insulating tape). Note to prevent the electromagnetic interference
(such as light switches and computers). It is recommended to use two-core wires over
16
0.3mm
2
as the connection wire between an exit button and a control panel.
3. Auxiliary input
inBIO160 provides one auxiliary input interface; inBIO260 provides two,
and inBIO460 provides four, which are connected to infrared body
detectors, smoke detectors, gas detectors, window sensor alarms, wireless exit
buttons, etc. Auxiliary inputs are set through relevant access control software.
For details, please refer to
Access5.0 User Manual.
Installation Guide for inBIO
4
60 Series Control Panel
Summary of Contents for inBIO460 Series
Page 1: ...Security at Fingertips www esslsecurity com...
Page 2: ......
Page 16: ...3 Connection and Installation inBIO260 terminal connection diagram 13...
Page 17: ...inBIO460 terminal connection diagram 14 Installation Guide for inBIO460 Series Control Panel...
Page 27: ...24 Installation Guide for inBIO460 Series Control Panel...
Page 37: ...between 485 and 485 34 Installation Guide for inBIO460 Series Control Panel...