In use of inBIO reader, all operations including storage, verification, etc. execute in
control panel. No need to re-register the fingerprints for reader changing. Realize
the real biometric reader connection.
1. Connected with inBIO readers
inBIO160 can connect two inBIO readers in the one-door two-way mode.
inBIO260 provides four readers, which can be connected in the two-door two-way
mode. inBIO460 provides eight readers, which can be connected in the two-door
two-way or four-door one-way mode.
485 reader connection: First of all, set the 485 address (device number) of reader by
software, DIP switch or keypad method. Such as the reader 1, 2 (the odd number is
for enter reader, and the even number is for exit reader), for example, the 485
address is 1, 2, and the door number is 1. For more information, please refer to the
software user manual.
Note:
In inBIO reader connection, if the reader shares the power with the
control panel, it is recommended that the wire should be less than 100 meters.
If you need to use in the longer distance, please use the separate power supply.
Connection between inBIO460 and inBIO Readers
2. Connected w
readers in the one-door two-way mode.
ith Wiegand readers
inBIO160 can connect two Wiegand
18
Installation Guide for inBIO
4
60 Series Control Panel
Summary of Contents for inBIO460 Series
Page 1: ...Security at Fingertips www esslsecurity com...
Page 2: ......
Page 16: ...3 Connection and Installation inBIO260 terminal connection diagram 13...
Page 17: ...inBIO460 terminal connection diagram 14 Installation Guide for inBIO460 Series Control Panel...
Page 27: ...24 Installation Guide for inBIO460 Series Control Panel...
Page 37: ...between 485 and 485 34 Installation Guide for inBIO460 Series Control Panel...