Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
20
door will remain open after a valid User Code 3, User Code 4 or
User Code 5 has been entered into the system.
Note: For controlling a garage door or electric gate, you will need
to set the door open time to 1 second.
2. Locate the Control Module, remove the cover and locate the
“PROGRAM” switch on the circuit board.
3. Press the PROGRAM switch once *. (The Keypad will beep
rapidly 4 times)
4. At the Keypad, enter 1-1-1-5 to open the memory (you will hear
three rapid beeps) and enter a combination of “1’s” (for every one
second increment) and “5’s” (for every five second increment)
that equal your desired Door Open Time. Each valid key press (a
“1” or a “5”) will generate a double beep. (Do not let more than
five seconds elapse between entries or the system will reset!!!)
Example: “1-1-1-5 1-1-5”
a
7 seconds
5. After entering your Door Open Time, wait five seconds for the 3
reset beeps.
Notes
: * Once the PROGRAM switch has been pressed, you have
2 minutes to begin programming. You will hear a double beep with
each valid key press. Once you begin entering the combination
of 1’s and 5’s do not let more than five seconds elapse between
entries or the system will reset!!! Maximum Door Open Time is
120
seconds
.