![Essex Electronics KE-265 Installation Instructions Manual Download Page 20](http://html1.mh-extra.com/html/essex-electronics/ke-265/ke-265_installation-instructions-manual_2428815020.webp)
Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
16
System Programming
Overview of System Code Programming
There are TWO levels of codes for the KE-265 system.
1. The Master Code (used to open the door and for programming
User Codes)
2. User Codes (used by personnel to open the door)
IMPORTANT
: Notes to remember before programming:
1. All codes must be 3 to 8 digits.
2. All codes must be different from each other.
Note
: 5-Pad Keypads have two digits on each pad.
The system reads these numbers as the same.
For example: 1-3-5-7-9 is the same as 2-4-6-8-0.
3. Do not program codes, which are part of other codes.
For example: User Code 1
a
1-2-3-4-5 and User
Code 2
a
1-2-3
4. During programming, the system resets after 5 seconds if a
number is not entered. Do not let more than 5 seconds elapse
between entries or the system will reset and you will have to start
over.
Overview of the Master Code
Knowledge of the Master Code is the highest privilege granted to a
user of the KE-265 system. There is only one master code, which
is used to program each of the 5 User Codes. The factory default
Master Code, “1-3-5-7-9”, can be used for initial programming but
should be changed to a unique 3 to 8 digit code.