background image

Installing the MGLS 

 

 

Care@Home™ Indoor Magnetic Sensor User Guide 

 

You can install the two MGLSs included in the kit as follows: 

 

On the main entrance door: The MGLS should be installed on the door from the inside of the 
premises out of reach of normal activity such that 

 

On the refrigerator door(s): For standard refrigerators, the MGLS should be installed out of 
reach of normal activity such that: 

For side-by-side refrigerators, install the smart magnetic sensor on one main door and the 
permanent magnet on the other main door. 

9.

 

Clean the surfaces of the mounting locations thoroughly. Make sure the locations are dry. 

 

 

 

NOTE: 

Refer to 

Using Screws

 in 

Appendix A,

 on page 16, for information about 

installing the MGLS using screws.

 

 

 

10.

 

Install the smart magnet sensor using mounting-tape: 

a.

 

Peel off the protective strip from the mounting-tape of the smart magnet sensor. 

b.

 

Press the smart magnet sensor into place. 

c.

 

Position the smart magnetic sensor and the permanent magnet at the same level, so that the 
alignment marks on the sides are in alignment, as illustrated in the following figure. 

The distance between the two parts of the device may vary from installation to installation, 
depending on the surface. For example, the molding on a door or window frame or the 
distance between the surfaces of a refrigerator door(s), due to rubber insulation, can require 
the smart magnetic sensor to be closer to the permanent magnet than the sensor would be in 
other installations. 

The two units of the MGLS must be placed, at most, 3 cm (1.2 in.) from each other. 

Summary of Contents for MGLS

Page 1: ...Care Home Indoor Magnetic Sensor User Guide ESUGSC007 Version 1 1 May 2017...

Page 2: ...mining the Best Location 4 2 3 Setting Up the MGLS 5 2 4 Testing the MGLS 9 3 Operating the MGLS 10 3 1 Indications 10 3 2 Notifications 11 3 3 Supervision 11 4 Replacing the Battery 12 5 Specificatio...

Page 3: ...detect when a door or window is opened or closed The MGLS is comprised of the following parts Smart magnetic sensor Permanent magnet Figure 1 Care Home Indoor Magnetic Sensor NOTE The images of batter...

Page 4: ...ards use GP International Limited batteries 2 2 Determining the Best Location Consider the following when selecting a mounting position for the MGLS A flat window or door surface A surface that is cle...

Page 5: ...LS is not from the Care Home kit you must add the MGLS to the Care Home system by pairing the MGLS device with the CP Press the Pairing button located on the right edge of the front of the CP for five...

Page 6: ...ton blinks blue three times If the pairing process is not successful the CP beeps and the ring lights up red for two seconds If the peripheral device is already paired the CP beeps and the ring lights...

Page 7: ...to confirm that the communication channel between the MGLS and the CP is established The handshake process is complete Figure 6 Green Communication LED on the CP 7 Attach the smart magnet sensor onto...

Page 8: ...for information about installing the MGLS using screws 10 Install the smart magnet sensor using mounting tape a Peel off the protective strip from the mounting tape of the smart magnet sensor b Press...

Page 9: ...the permanent magnet a Peel off the protective strip from the mounting tape of the permanent magnet b Press the permanent magnet into place 2 4 Testing the MGLS When the battery is installed perform...

Page 10: ...ises The refrigerator door to monitor the Resident s dining routine When the MGLS is operational and a break in the contact with the magnet is detected the smart magnetic sensor sends an event to the...

Page 11: ...configured temperature thresholds The battery charge for the MGLS is low requiring replacement The tamper switch in the MGLS is disturbed registering a tamper event Use the Care Home CMS software appl...

Page 12: ...in the cover release tab as illustrated in Figure 2 on page 5 and press the tab to release the back cover 2 Remove the old battery 3 Press the tamper switch several times to release the residual stati...

Page 13: ...tional End to End Bi Directional ESI protocol Advanced radio supervision algorithm Frequency FSK modulation 869 225 MHz 868 3 MHz Europe and China 916 5 MHz North America and Australia 800 MHz Israel...

Page 14: ...et sensor 45 g incl battery 0 1 lb Permanent magnet 25 g 0 06 lb Color RAL 9003 Glossy White Compliance with Standards CE EMC Radio Safety The following table defines the technical data about the batt...

Page 15: ...uble sided adhesive tape Before choosing the installation method consider the following The permanent magnet is only installed using the double sided adhesive tape Installation with the adhesive tape...

Page 16: ...Acrylic Polyurethane paint Polyester Paint Using Screws The mounting base has two holes The thin plastic covering over the holes can be removed if necessary You can drill through the tape if needed Re...

Page 17: ...se with Screws 2 Place and hold the mounting base on the desired mounting location 3 Mark the drilling spots through the above mentioned punch outs 4 Drill the holes 5 Insert two 2 wall anchors in the...

Page 18: ...e laws apply to you some or all of the above disclaimers exclusions or limitations may not apply to you By using the information contained herein you agree that the laws of the State of Israel without...