![Espa Evopool SilenPlus Instruction Manual Download Page 14](http://html1.mh-extra.com/html/espa/evopool-silenplus/evopool-silenplus_instruction-manual_2427709014.webp)
14
EN
11. LED INDICATORS
In
SilenPlus
pump
::::
The possible LED combinations and their meanings are:
0 = LED OFF
1 = LED ON
2 = LED flashing slowly
3 = LED flashing quickly
MAN/
FAULT
BACKWASH
Plus
Plus
Plus
Plus
FILTRATION
Plus
Plus
Plus
Plus
Equipment status
Functions
0
0
1
Filtration Plus
function in Remote mode.
0
1
0
Backwash Plus
function in Remote mode.
0
1
1
Mixed Cycle function in Remote mode. Motor at 100%.
1
0
1
Filtration Plus
function in Manual mode.
1
1
0
Backwash Plus
function in Manual mode.
1
1
1
Mixed Cycle function in Manual mode.
2
0
0
“Standby" mode. The equipment has power, motor stopped.
a) Valve in intermediate positions or position 6 in Remote mode.
b) Stop function in Manual mode.
c) Timer OFF position.
0
0
2
Filterwatch
function active.
0
3
2
With
Filterwatch
active: Filter saturated, please clean it.
Configuration
3
3
3
Initial configuration: standing by for link with
ControlSystem
( . . . t oget her . . . )
3
0
1
Filtration Plus
speed setting.
3
1
0
Backwash Plus
speed setting.
3
1
1
Mixed Cycle speed setting.
0
0
3
(3 times)
Activation/deactivation of the
Filterwatch
function
Errors
2
1
2
No water error. Start-up retry attempted.
2
1
1
No water error. Full shut-down.
When moving the control
of the
ControlSystem:
Number of flashes
ControlSystem status
3
The
ControlSystem
is not linked to any
SilenPlus.
2
Communication error. Call for service.
1
The
ControlSystem
works correctly.
0
Replace the
ControlSystem
battery