6. DISPOSING OF THE PRODUCT 

When  the  pump  is  eventually  disposed  of,  please 
note  that  it  contains  no  toxic  or  polluting  material. 
All main components are material identified to allow 
selective disposal.

 

This product or parts of it must be disposed of in an 
environmentally  sound  way,  use  the  waste 
collection service. 

8. TECHNICAL DATA 

Liquid temperature… ..................... .4ºC - 40ºC 
Ambient temperature: ..................... 0ºC - 40ºC 
Storage temperature: 

-10ºC - 50ºC

 

Ambient relative humidity, max.: ............... 95% 
Motor class 

I

Start up pressure: ......................... 1.5 

– 2.5bar 

Other data see Figure 1. 

 
 
 
 
 
 
 
 
9. POSSIBLE FAULTS, CAUSES AND SOLUTIONS 

1) 

The motor does not start.

 

2) 

Motor operates but there is no pressure.

 

3) 

Motor over-heating.

 

4) 

Pump does not deliver rated capacity.

 

5) 

The assembly is constantly stopping and 
starting.

 

6) 

The assembly does not shut down

 

7. 

PLATE SHOWING CHARACTERISTICS

 

 

 

DESCRIPTION 

Item reference

 

V fre item specifications

 

Flow 

Pressure 

Nominal voltage, no. stages, alternate current symbol and frequency

 

Capacitor (Single-phase model) 

EC mark 

Humidity protection level

 

Maximum pressure

 

10 

Year and week of manuf Pump serial number

 

11 

Thermal protection incorporated indicator 

12 

Max. liquid temperature

 

13 

Motor max. nominal output (P2) 

14 

Electric pump unit absorbed power(P1)

 

15 

Designated motor insulation

 

16 

Continuous operation symbol

 

17 

Maximum nominal intensity at nominal voltage

 

18 

Name and address of vendor responsible for the product

 

 

1

 

2

 

3

 

4

 

5

 

6

 

POSSIBLE PROBLEM

 

SOLUTIONS 

 

X

   

 

  X   

Pump blocked

 

Disconnect it and take it to the official Technical Service

 

 

 

  X   

 

Foot valve clogged

 

Clean it or replaced by new one

 

 

X

   

X

   

 

Total head higher than expected 

Verify geometric head and loss of head

 

X

    X   

X

   

Wrong tension

 

Check that the tension is the same as that on the 
name plate

 

 

X

   

X

   

 

Water level in well or tank has come 
down

 

Verify suction head

 

X

   

 

 

 

 

Fuse or thermal relay disconnected

 

Change fuse or thermal relay

 

  X   

X

   

 

Impellers are worn out

 

Disconnect pump and take it to your Service Dealer

 

 

X

   

 

 

 

Foot valve not submerged

 

Be sure suction pipe is submerged

 

 

X

   

 

 

 

Pump was not primed

 

Fill pump body with water

 

 

  X   

X

   

Room not properly aired

 

Provide good ventilation

 

 

X

   

 

 

 

Air entry

 

Seal unions and joints properly

 

 

 

 

 

 

Closed gate valve 

 

Open valve

 

 

 

 

  X  X 

Tap or cistern leak 

 

Repair leak

 

 

 

 

 

 

No water 

 

Wait till water level recovered and press reset button

 

 

 

 

  X 

Leak in discharge pipework 

 

repair leak

 

 

 

 

 

 

The  static  head  is  greater  than  the 
assembly start pressure

 

Check start-up setting is correct

 

Summary of Contents for MISTRAL KIT L

Page 1: ...FR Manuel d instructions Traduction de l original en espagnol 12 DE Gebrauchsanweisung bersetzungausdem Original in Spanisch 16 IT Manuale d istruzioni Traduzione dall originale spagnolo 20 PT Manual...

Page 2: ......

Page 3: ...e EN 809 et la EN 60204 1 Directive Compatibilit Electromagn tique 2014 30 UE Norme EN 61000 6 1 et EN 61000 6 3 Directive Basse Tension 2014 35 UE Norme EN 60335 1 et EN 60335 2 41 Directive 2009 125...

Page 4: ...65 UE RoHS II Norme EN 50581 Veja o n mero de s rie na placa de identifica o NL VERKLARING VAN OVEREENSTEMMING Wij verklaren onder onze verantwoordelijkheid dat de producten in deze handleiding voldoe...

Page 5: ...as causas y soluciones 8 9 Datos t cnicos 8 10 Lista de componentes principales 36 11 Ilustraciones 37 Advertencia para la seguridad de personas y cosas La siguiente simbolog a junto a un p rrafo indi...

Page 6: ...posible del nivel del agua a fin de reducir el recorrido de aspiraci n para evitar p rdidas de carga Es imprescindible que la tuber a de aspiraci n quede sumergida por lo menos 30 cm por debajo del n...

Page 7: ...uipo s lo puede ser efectuada por un servicio t cnico autorizado La Relaci n de Servicios T cnicos Oficiales se encuentra en www espaleader eu 6 ELIMINACI N DEL PRODUCTO Llegado el momento de desechar...

Page 8: ...obar que la tensi n sea igual a la marcada en la placa de caracter sticas X X Disminuci n del nivel de agua en el pozo Regular la altura de aspiraci n X Fusible o rel t rmico desconectado Cambiar el f...

Page 9: ...risk level deriving from failure to observe the prescribed safety precautions DANGER risk of electric shock Warns that failure to observe the pre cautions involves a risk of electric shock DANGER Warn...

Page 10: ...e needs to be installed 3 4 Electrical connection Single phase motors have thermal protection 3 5 Pre start checks Ensure the voltage and frequency of the supply corresponds to the values indicated on...

Page 11: ...protection incorporated indicator 12 Max liquid temperature 13 Motor max nominal output P2 14 Electric pump unit absorbed power P1 15 Designated motor insulation 16 Continuous operation symbol 17 Maxi...

Page 12: ...aque signal tique 14 8 Pannes ventuelles causes et solutions 15 9 Donn es techniques 15 10 Liste des composants principaux 36 11 Illustrations 37 Avertissements pour la s curit des personnes et des ch...

Page 13: ...Le tuyau d aspiration doit tre immerg au moins 30 cm sous le niveau dynamique de l eau Fig 4 3 3 Pose des tuyaux de refoulement Il est conseill d utiliser des tuyaux de refoulement d un diam tre gal...

Page 14: ...manipulation de la pompe ne doit tre effectu e que par un Service Technique Officiel La relation des services techniques officiels est en www espaleader eu 6 MISE AU REBUT Si arrive le moment de mettr...

Page 15: ...d fectueux Remplacez le fusible ou faites le r armement thermique X X Usure des turbines D montez et rendez vous au Service technique agr X Clapet de pied non submerg e Submergez convenablement le tuy...

Page 16: ...Typenschild 18 8 M gliche oefekte ursachen uno abhilfe 19 9 Technische Daten 19 10 Liste der Hauptkomponenten 36 11 Abbildungen 37 Sicherheitshinweise ftir Personen und Sachen Die Symbole und die Begr...

Page 17: ...n mit einem Mindestgef lle von 2 verlegt werden Es ist zwingend notwendig dass die Saugleitung mindestens 30cm unter der dynamischen Wasserstand berflutet Abb 4 3 3 Verlegung der Druckleitung Die Druc...

Page 18: ...Eingriffe f hren zum Erl schen der Garantie Die Technische Dienstleistungen Verzeichnis ist im www espaleader eu 6 ENTSORGUNG DES PRODUKTS Wenn die Pumpe schlie lich entsorgt wird beachten Sie bitte...

Page 19: ...en tzte Laufr der Ausbauen und technischen Kundendienst verst ndigen X Fussventil liegt oberhalb des Wasserspiegels Saugstutzen unterhalb des Wasserspiegels bringen X Ansaugphase der Pumpe wurde berga...

Page 20: ...Dati tecnici 23 10 Elenco dei principali componenti 36 11 Illustrazioni 37 Avvertimenti per la sicurezza delle persone e delle cose Questa simbologia assieme alle relative diciture Pericolo e Avverten...

Page 21: ...ottenere el minor persorso d aspirazione possibile riducendo cos le perdite di carico imprescindible collocare il tubo d aspirazione sommerso circa 30cm al di sotto del livello dinamico dell acqua Fig...

Page 22: ...della pompa potranno essere eseguiti soltanto da un servizio di assistenza tecnica ufficiale L elenco dei servizi tecnici autorizzati in www espaleader eu 6 SMALTIMENTO DEL PRODOTTO Quando sar il mome...

Page 23: ...ermico X X Usura delle turbine Smontare la pompa e rivolgersi al Servizio Tecnico Ufficiale X Valvula di fondo non immersa Immergere adeguatamente il tubo d aspirazione X Dimenticanza d innescare la p...

Page 24: ...nimo 26 5 Manuten o 26 6 Elimina o do produto 26 7 Chapa de caracter sticas 26 8 Poss veis avarias causas e solu es 27 9 Dados t cnicos 27 10 Lista dos componentes principais 36 11 Ilustra es 37 Adve...

Page 25: ...nivel de gua a fim de reduzir as perdas de carga imprescindivel a coloca o do tubo de aspira o submerso pelo menos 30cm abaixo do nivel din mico do gua Fig 4 3 3 Montage dos tubos de co press o Procu...

Page 26: ...mba s dever ser realizada por um servi o t cnico autorizado A lista de servi os t cnicos autorizados est na www espaleader eu 6 ELIMINA O DO PRODUTO No final do tempo de vida til da bomba esta n o con...

Page 27: ...ulsores Desmonte e levar o um servi o t cnico oficial X V lvula de p n o submersa Sumergir adecuadamente o tubo de aspira o X Bomba sem gua Encher o corpo da bomba com agua X X M ventila o do local Ob...

Page 28: ...gelijke storingen oorzaken en oplossingen 31 9 Technische gegevens 31 10 Lijst van de voornaamste onderdelen 36 11 Afbeeldingen 37 Veiligheidsvoorschriften voor personen en materieel De volgende symbo...

Page 29: ...ht mogelijk bij het waterpeil ge nstalleerd om de afstand van het aanzuigtraject te verkorten en drukverliezen te voorkomen Het is van wezenlijk belang dat de aanzuigleiding ten minste 30cm onder de d...

Page 30: ...bewerkingen aan de pomp uitvoeren De lijst Erkende Technische Diensten vindt u op www espaleader eu 6 AFVOEREN VAN HET PRODUCT De pomp bevat geen giftige of verontreinigende materialen waar u rekenin...

Page 31: ...ervangen X X Turbines versleten Pomp uitbouwen en naar Erkende Technische Dienst brengen X Voetventiel niet onder water Aanzuigleiding correct onder water brengen X De pomp vergeten te vullen Pompbehu...

Page 32: ...32 RU 7 A I 8 B C 3 D 0 03 E J F K G L H 32 1 32 2 33 3 33 3 1 33 3 2 33 3 3 33 4 34 4 1 34 4 2 34 4 3 34 5 34 6 34 7 35 8 35 9 36 10 37 1 40 KIT c KIT 1 KIT KIT 0 7...

Page 33: ...33 RU 2 3 o KIT 1 2 KIT M KIT 10 3 1 5 10 30 3 KIT KIT 3 2 3 3 4 4 1 10 10 RESET 10...

Page 34: ...34 RU 4 2 KIT KIT 1 5 15 1 KIT RESET 4 3 1 10 5 www espaleader eu 6 1 2 3 4 5 6 7 CE 8 9 10 11 12 13 P2 14 P1 15 16 17 18...

Page 35: ...35 RU 7 1 2 3 4 5 6 8 4 C 40 C 0 C 40 C 10 C 50 C 95 I 1 5 2 5bar 1 1 2 3 4 5 6 X X X X X X X X X X X X X X X X X X X X X X X X X X X...

Page 36: ...or shaft Arbre de moteur Motorwelle 11 Ventilador Fan Ventilateur L fterrad 12 Tapa ventilador Fan cover Capot ventilateur L fterhaube 13 Kit02 Kit02 Kit02 Kit02 IT PT NL RU 1 Coperchio aspirante Tapa...

Page 37: ...37 Fig 1 Abb 1 Afb 1 1 Fig 2 Abb 2 Afb 2 P c 2 Fig 3 Abb 3 Afb 3 P c 3...

Page 38: ...38 Fig 4 Abb 4 Afb 4 P c 4 Fig 5 Abb 5 Afb 5 P c 5 0 10 0 5 Fig 6 Abb 6 Afb 6 P c 6 Fig 7 Abb 7 Afb 7 P c 7 A B C D E F G H I J K L Pmax 10 bar...

Page 39: ......

Page 40: ...C d 210603 04 2021 1 MEBA S L U GIRONA SPAIN www espaleader eu...

Reviews: