12. Tooling System
Knife Blades are extremely sharp.
Take care when handling Knife Tools.
Laser Radiation.
Do not stare into beam!
The tool head is equipped with a class II laser pointer. Emitted laser
power < 1 mW.
12.1 Tool handling and care
All tools are precision instruments and should be treated as such to ensure proper operation.
Take special care when:
•
Tools
are inserted or removed
from their stations. No excessive
force should be applied.
•
Tools
should not come in
contact with hard surfaces while
removed from their stations either
temporarily or for storage.
• The
Tools
and their stations
should be kept clean with a soft
brush.
12.2 Tool Inserts with built-in motor
Some of the tool inserts has a built-in motor, such as the reciprocating knife tools, RotaCut and
the FlexiDrillTool.
Only one motor drive outlet is available, thus, the number of such tools that can be used at the
same time is limited to one.