12
Kongsberg XN / iPC 2.0
89
Keep distance d small
For best performance and minimum wear, do
not let the bit stick out more than necessary.
Use bits with short cutting lengths for thin
materials.
Chuck Open/Close valve operation
Never operate the
Chuck Open/Close valve
while the spindle is running.
This will destroy
the spindle.
Air Pressure and Quality
Never run IBAG spindle with
Pressurized Air
disconnected.
This may destroy the spindle.
Keep this in mind also for test purposes.
Use clean air
Never run IBAG spindle with
Pressurized Air
disconnected.
This will destroy the
Spindle
.
Use Clean Air
The
Spindle
is sensitive for the
Pressurized
Air
quality.
Regularly check the
Air Pressure Reduction
Valve
according to the
Maintenance
on page
147 section.