Manufacturer Specific Profile Area
CAN-CBX-AI420
Manual • Doc.-No.: C.3030.21 / Rev. 1.4
Page 89 of 103
7.11.2 Sample Time Set Point (2310
h
)
Index
Sub-
index
Description
Value range
Default
Data type
Access
mode
2310
h
0
Number of entries
1
1
unsigned 8
ro
1
Sample_Time_Set_Point
82
h
... 14FC
h
4994
unsigned 16
rw
This object transmits the setpoint of the sample time. The setpoint is evaluated for the setting of the
sample time of all four A/D-channels. The smaller the output data rate is chosen, the higher is the
resolution of the measured values reached.
Assignment of the variable Sample_Time_Set_Point:
The setpoint of the sample time can be set in 0.5
Ù
s steps:
Examples:
Examples for variable values of
Sample_Time_Set_Point _x
Set point of the
sample time
Output Data
Rate
Effective
Resolution
(at ±10 V)
[9]
Hexadecimal
Decimal
0082
h
130
65
Ù
s
15 384,6 Hz
Ú
17 Bits
0083
h
131
65,5
Ù
s
15 267 Hz
Ú
17 Bits
00A4
h
164
82
Ù
s
12166 Hz
17,3 Bits
019E
h
414
207
Ù
s
4 826 Hz
19.0 Bits
0316
h
789
395
Ù
s
2 534 Hz
19,5 Bits
03E5
h
998
499
Ù
s
2005 Hz
19,7 Bits
07CE
h
1998
999
Ù
s
1001 Hz
20.3 Bits
1382
h
4994
2497
Ù
s (Default)
400 Hz
21 Bits
14FC
h
5372
2686
Ù
s
372 Hz
21 Bit
The table above shows the technically reasonable limit values with their effective resolutions (at
±10 V)