Device Profile Area
CAN-CBX-AI420
Manual • Doc.-No.: C.3030.21 / Rev. 1.4
Page 85 of 103
7.10.7 Interrupt Upper Limit (6424
h
)
Index
Sub-
Index
Description
Value range
Default Data type
Access
mode
6424
h
0
Number_of_entries
4
4
unsigned 8
ro
1
Analog_Input_Interrupt_Upper_Limit_1
80000000
h
...
7FFFFFFF
h
0
integer 32
rw
2
Analog_Input_Interrupt_Upper_Limit_2
80000000
h
...
7FFFFFFF
h
0
integer 32
rw
3
Analog_Input_Interrupt_Upper_Limit_3
80000000
h
...
7FFFFFFF
h
0
integer 32
rw
4
Analog_Input_Interrupt_Upper_Limit_4
80000000
h
...
7FFFFFFF
h
0
integer 32
rw
The object Analog_Input_Interrupt_Upper_Limit defines the upper limit for the interrupt function.