-- 55 --
fzb2d3ea
12.12 CALIBRATION MENU
Cable area (mm2)
X
Weldhead offset, mm
START SEQUENCE MENU
STOP SEQUENCE MENU
CALIBRATION MENU
DISPLAY MENU
ERROR LIST
Test
0 / 1 / 2
Choosing the
CALIBRATION MENU
the following menu comes up:
Current at PEH %
100
Voltage at PEH %
100
Current at head %
100
Voltage at head %
100
Travel speed %
100
Wire speed %
100
Current at PEH %
Shows the real value in the PEH display expressed as a percentage of the desired
current reference value.
Voltage at PEH %
Shows the real value in the PEH display expressed as a percentage of the desired
voltage reference value.
Current at head %
Shows how many per cent the set reference value constitutes of the measured
current value at the welding head. This also affects the real value in the PEH display.
Voltage at head %
Shows how many per cent the set reference value constitutes of the measured
voltage value at the welding head. This also affects the real value in the PEH display.
Travel speed %
Adjustment as a percentage of the measured speed of the travel motor in relation to
the speed desired (valid for LINEAR 1).
Wire speed %
Adjustment as a percentage of the measured speed of the wire feed motor in relation
to the speed desired
.
GB