12.4 Gas preflow (s) (only for GMAW)
Product code
A2TFH
Weld process
SAW
POWER SOURCE MENU
Gas preflow (s)
1--99
Gas postflow (s)
1--99
Password
XXXXX
Cable length (m)
X
Cable area (mm2)
X
The protective gas must start to flow before the arc is struck in order to provide time
for it to cover the weld position. A suitable preflow time must therefore be loaded
into the system, and this is done by entering the required time, in seconds, into the
selected field.
Times between 1 and 99 seconds can be entered. The default value is 1 second.
12.5 Gas postflow (s) (only for GMAW)
Product code
A2TFH
Weld process
SAW
POWER SOURCE MENU
Gas preflow (s)
1--99
Gas postflow (s)
1--99
Password
XXXXX
Cable length (m)
X
Cable area (mm2)
X
The protective gas must continue to flow after the arc is extinguished in order to
protect the weld while it cools. A suitable postflow time must therefore be loaded
into the system, and this is done by entering the required time, in seconds, into the
selected field.
Times between 1 and 99 seconds can be entered. The default value is 2 seconds.