-- 31 --
fzb2d3ea
The wire feed motor and wire feed axis are automatically set when either
A2TFE,
A2TGE, A2TFH, A2TGH, A6TFE, A6 TGE, A6TFH
or
A6TGH
have been selected.
Table for program version 4.0 and 4.01:
Wire feed axis (wire feed motor):
A2TFE
A2TGE
A2TFH
A2TGH
A6TFE
(
*1
)
A6TGE
Motor
FHP36
FHP68
FHP36
FHP68
VEC4000
VEC8000
Gear1
49:1
49:1
49:1
49:1
156:1
74:1
Gear2
1:1
1:1
1:1
1:1
1:1
1:1
P.D.mm
49
49
49
49
49
49
Encoder ppr
6
0
6
0
0
0
Low manual speed
150
150
150
150
150
150
High manual speed
300
300
300
300
300
300
Travel axis (travel motor):
A2TFE
A2TGE
A2TFH
A2TGH
A6TFE
(
*2
)
A6TGE
Motor
DUNKER2 DUNKER2 FHP258
FHP258
DUNKER1 DUNKER1
Gear1
750:1
750:1
24:1
24:1
375:2
375:2
Gear2
158:100
158:100
51:1
51:1
427:100
427:100
P.D.mm
158
158
158
158
180
180
Encoder ppr
0
0
6
6
0
0
Low manual speed
100
100
100
100
100
100
High manual speed
200
200
200
200
200
200
Table for program version 4.2, 4.3, 5.0 and 5.1:
N.B.
For A6 Mastertrac with serial number 232 or earlier use motor data (
*1
) and (
*2
).
Wire feed axis (wire feed motor):
A2TFH
A2TGH
A6TFH
A6TGH
Motor
FHP36
FHP68
VEC4000
VEC8000
Gear1
49:1
49:1
156:1
74:1
Gear2
1:1
1:1
1:1
1:1
P.D.mm
49
49
49
49
Encoder ppr
6
0
0
0
Low manual speed
150
150
150
150
High manual speed
300
300
300
300
Travel axis (travel motor):
A2TFH
A2TGH
A6TFH
A6TGH
Motor
FHP258
FHP258
FHP258
FHP258
Gear1
24:1
24:1
24:1
24:1
Gear2
51:1
51:1
51:1
51:1
P.D.mm
158
158
180
180
Encoder ppr
6
6
6
6
Low manual speed
100
100
100
100
High manual speed
200
200
200
200
GB