-- 52 --
fzb2d3ea
Example
:
Time
0,1s
20
Speed
%
100
Voltage
%
50
Current
%
100
Wire feed
%
100
Time
0,1s
30
Speed
%
100
Voltage
%
70
Current
%
100
Wire feed
%
100
START PHASE 1
START PHASE 2
100 %
Phase 1 = 2,0 s
Phase 2 = 3,0 s
70 %
voltage
50 %
Current, voltage and speed are adjusted by
indicating a percentage value of the welding
parameters on the main menu.
Max. adjustable value is 150% as long as the
capacity of the welding power source and the
max. possible welding speed are not exceeded.
Preset value is 100.
When the welding parameters are changed through the over--ride function, the
values in the start sequence are changed correspondingly, see the Instruction
manual.