Analog Controls and Displays (cont.)
Switch Chart A - Output Board PSOPT-1
SWITCHES AND JUMPERS
SWITCH
POSITION/SETTING
POSITION/SETTING
SW1-1
UP
Reject confirmation is OFF
DOWN Reject confirmation is ON
SW1-2
UP
Timed output is manually reset
DOWN Timed output is automatically reset
SW1-3
Sets the length of the Shift Register. See Switch Chart B.
SW1-4
Sets the length of the Shift Register. See Switch Chart B.
SW1-5
Sets the length of the Shift Register. See Switch Chart B.
SW1-6
Sets the length of the Shift Register. See Switch Chart B.
SW1-7
Sets the length of the Shift Register. See Switch Chart B.
SW1-8
Sets the length of the Shift Register. See Switch Chart B.
SW1-9
UP
Direct output is manually reset
DOWN Direct output is automatically reset
SW2-1
UP
MODE 1 detection
DOWN MODE 2 detection
SW2-2
UP
Indexed reject
DOWN Standard reject
SW2-3
UP
Tachometer input
DOWN Internal clock
SW2-4
UP
SSR output is normally closed
DOWN SSR output is normally open
JP1
ON
Not always space between packages
OFF
Always space between packages
JP2
ON
Travel time (0.30sec - 50sec,
±
10sec)
OFF
Travel time (0.05sec -10sec,
±
2sec)
JP3
ON
10sec reject inhibit at power on
OFF
Reject enabled at power on
JP1
This jumper is to set up the metal detector
when a proximity sensor is used. If there is
always a space between packages, then JP1
i s O F F ( o p e n ) . W h e n a s p a c e b e t w e e n
packages cannot be guaranteed, then JP1 is
ON (shorted).
JP2
T h i s j u m p e r i s u s e d t o s e t t h e r a n g e o f
adjustment the TRAVEL TIME has. When JP2
is ON (shorted) the TRAVEL TIME has an
a d j u s t m e n t r a n g e o f 0 . 3 0 s e c o n d s t o 5 0
seconds. When JP2 is OFF (open) the TRAVEL
TIME adjustment has a range of 0.05 seconds
to 10 seconds. JP3 This jumper is used to
inhibit the reject during power up. With JP3 ON
(shorted the DIRECT RELAY and the TIMED
RELAY outputs will not reject until the power
to the metal detector has been on for 10
seconds. When JP3 is OFF (open) the DIRECT
RELAY and TIMED RELAY will be active as
soon as power is turned on.
Summary of Contents for E-Z TEC IV
Page 58: ...58 Figures cont Figure 5 Detect Modes...
Page 62: ...62 Figures cont Figure 12 Metal Detector Mounting Feet Figure 13 Conveyor Belt Splices...
Page 63: ...63 Figures cont Figure 14 Electrical Connections...
Page 64: ...64 Figures cont Figure 15 Analog Version Control Panel...
Page 67: ...67 Figures cont Figure 19 Flowchart of MPC Menu Structure...
Page 98: ...98 This Page Intentionally Left Blank...