Ethernet: Control
Overview
The Base Chassis has two Ethernet control ports that support IEEE 802.3 100BASE-TX and 1000BASE-T protocols. The control ports
are accessible via RJ-45 connectors mounted on the rear panel of the unit.
Ethernet Control Port Numbering
The Ethernet control ports are used to connect the unit to a web browser or the control system (nCompass Control [V6.5 onwards]).
Ethernet Control Port Parameters
NOTE :
Control via the Data input ethernet ports is not supported
A single IP port is defined for all ethernet control of the chassis. The physical ports used for ethernet control are by default the
control ethernet ports. The control ports can raise an alarm during abnormal operational conditions, (see Looking After the Unit >
Troubleshooting > Handling Alarms >
Alarms - Control Port
).
The parameters defining the control ethernet port are as shown in the following table
Parameter
Values
Description
Comments
Control Port Parameters
Primary Port
Ctrl1
Primary control port
Ctrl2
Secondary control port
Auto
Automatic selection of control
port
Auto-revert delay
0 seconds
No automatic switch back to
primary network
1 to 999 seconds [default
120]
Duration n seconds of how
long the primary link must be
restored for, before the control
will switch back to it
Default MAC Address
aa:bb:cc:dd:ee:ff
Control ports MAC address as
defined by P790. (This cannot
be changed by the user)
Read only parameter for information
Control Port IP Configuration
IP Address
aaa.bbb.ccc.ddd
IP address of the control port
Subnet Mask
0.0.0.0 [default]
Subnet mask for the control
port
aaa.bbb.ccc.ddd
Gateway Address
0.0.0.0 [default]
No defined gateway
aaa.bbb.ccc.ddd
Gateway address for packets
outside the defined control
© Ericsson AB 2011. All rights reserved