![Ericsson 1553-FGC 101 1010 Uen A Handbook Download Page 146](http://html1.mh-extra.com/html/ericsson/1553-fgc-101-1010-uen-a/1553-fgc-101-1010-uen-a_handbook_2423331146.webp)
correctly, and
that the
ambient
temperature
is not
excessive.
Over Temperature
Base Unit
Host
0
00000443
1091
internal
Failure to
take action
may cause
permanent
damage to
the chassis.
Please switch
off and refer
to Customer
Support.
Power On Self Test Failure
Base Unit
Host
0
00000444
1092
internal
At least one
start-up test
has failed.
Problems
amy be
experienced
with the
normal
operation of
the chassis.
+12V A Failed
Base Unit
Host
0
00000445
1093
internal
+12V A rail
has failed.
Please check
supply or
contact
Customer
Support.
+12V B Failed
Base Unit
Host
0
00000446
1094
internal
+12V B rail
has failed.
Please check
supply or
contact
Customer
Support.
Real Time Clock
Base Unit
Host
0
00000447
1095
internal
The Real-time
clock has
failed. The
time/date
will not be
stored
between
power-ups.
NTP Server Response Timeout
Base Unit
Host
0
00000448
1096
internal
The chassis
could not
contact the
NTP Server.
The
time/date
will drift over
time.
Internal Hardware Issue
Base Unit
Host
0
00000449
1097
internal
An Internal
Hardware Issue
has occured.
The system
may not
function
properly.
Host Build Version Mismatch
Base Unit
Host
0
0000044A
1098
internal
Host software
is not at an
officially
released
version. Host
function may
not be
affected.
The system
27 MHz VCXO
Page 146 of 153
Cover
9/11/2012
file://C:\Users\ebriacl\AppData\Local\Temp\~hh7DF.htm