![Ericsson 1553-FGC 101 1010 Uen A Handbook Download Page 148](http://html1.mh-extra.com/html/ericsson/1553-fgc-101-1010-uen-a/1553-fgc-101-1010-uen-a_handbook_2423331148.webp)
HD H.264 VCM Alarms - EN8190
The following table lists the alarm and failure identifiers generated by the HD H.264 VCM.
HD H.264 Pre-Processor Module
Referenced Output Stream
Unavailable
Base Unit
Slot 1 to Slot 6
0
00000461
1121
internal
card is not
installed in
the specified
slot or it
cannot
provide the
requested
output
stream.
Name
Module
Slot
Port
ID (hex)
ID (dec)
Type
Description
Over Temperature
Warning
EN8190 Pre-
Processor
Module
Slot 3
0
000C0001
786433
internal
Failure to take action may cause
permanent damage to the chassis.
Please check the fans are working
correctly, and that th eambient
temperature is not excessive.
Over Temperature
EN8190 Pre-
Processor
Module
Slot 3
0
000C0002
786434
internal
Failure to take action may cause
permanent damage to the chassis.
Please switch off and refer to
Customer Support.
Invalid Parameter
EN8190 Pre-
Processor
Module
Slot 3
0
000C0003
786435
internal
Invalid Parameter received by the
Video/Audio Module. Please see Video
Encoder status for a more detailed
description of the error.
Video/Audio
Module Error
EN8190 Pre-
Processor
Module
Slot 3
0
000C0004
786436
internal
Video/Audio Module Error. Please see
Video Encoder status for a more
detailed description of the error.
Power On Self
Test Failure
EN8190 Pre-
Processor
Module
Slot 3
0
000C0006
786438
internal
At least one start-up test has failed.
Problems may be experienced with the
normal operation of the chassis.
Internal HW
Information
EN8190 Pre-
Processor
Module
Slot 3
0
000C0007
786439
internal
HW reported an unexpected status
value. This does not effect normal
operation of the chassis.
Option Card Build
Version Mismatch
EN8190 Pre-
Processor
Module
Slot 3
0
000C0008
786440
internal
The software on this option card is not
an officially released version.
SMPTE334 Closed
Captions Input
Lock
EN8190 Pre-
Processor
Module
Slot 3
1
000C0009
786441
input
No valid SMPTE334 Closed Captions
can be detected
Video Processor
Boot Failure
EN8190 Pre-
Processor
Module
Slot 3
1
000C0010
786448
internal
At least one video processor has not
booted
Video Processor
Alive Count
Failure
EN8190 Pre-
Processor
Module
Slot 3
1
000C0011
786449
internal
At least one video processor has not
incremented its alive count
Timecode
Locked
EN8190 Pre-
Processor
Module
Slot 3
1
000C0012
786450
input
Timecode
extraction is on but no
timecode is present
Video Input Lock
EN8190 Pre-
Processor
Module
Slot 3
1
000C0005
786437
input
No valid video found on video input.
Please check source connection.
Audio1 DD Pass
Thru sync loss
Audio Module
Slot 3
0
000C0041
786497
input
Audio and Video were not locked prior
to encoder input.
Audio1 Input Lock
Audio Module
Slot 3
0
000C0042
786498
input
No valid audio found on selected input.
© Ericsson AB 2011. All rights reserved
Page 148 of 153
Cover
9/11/2012
file://C:\Users\ebriacl\AppData\Local\Temp\~hh7DF.htm