FS2003 ISP
Programmer - User Guide V1.07 – 1
st
September 2007
50
3.6.3 Standalone Keypad Operation – step-by-step guide
The instructions below detail how to operate the programmer in Standalone Mode using the
programmer keypad and LCD. A PC is not required while operating in Standalone Mode.
1. Ensure that you have already uploaded a valid ‘Project Collection’ to the programmer
•
Use the EQTools – Upload Wizard to upload your ‘Project Collection’.
•
Use the new Standalone Upload Wizard Utility to upload your ‘Project Collection’. (software
upgrade required)
2. Select the ‘Programming Project’ which you wish to execute:
•
Use the <UP> and <Down> keys to move up and down the list of projects currently resident in
the programmer ‘FLASH Memory Store’.
•
If there is one ‘Programming Project’ resident in the programmer, then this project will be
displayed permanently on the LCD.
•
If Project Version Control has been enabled for the project(s), then the project version
information will be displayed on the bottom line of the LCD.
LCD Display
Buttons
Status LED
Display
Select Project
Project1
Select Project
Project2
Select Project
Project3
3. Press the RED <YES> button to select the Programming Project
LCD Display
Buttons
Status LED
Display
Select Project
Project1