3.5.5 Buffer Window - Control Buttons
The Buffer Window within EDS is used as a virtual data store which allows data to be transferred from
file
Æ
Buffer Window
Æ
Target Device and vice-versa.
The ‘Buffer – Control Buttons’ support operations on the data in the Buffer Window, including loading
a file into Buffer or saving the contents of the Buffer to file. These buttons do NOT initiate any actual
programming operation of the Target Device.
#
Button
Description / Purpose
1
Re-load File
•
Re-loads the specified HEX / Binary file into the Buffer Window.
2
Edit Buffer
•
Tick the box to enable manual editing of the Buffer Window.
•
This will also allow the <Load>, <Erase> and <Fill> buttons to be
selected.
3
<Load>
•
This button allows you to manually browse to select a file to be load
into the Buffer Window.
•
The path will default to the path set up in the Programming Project
(if a file is specified).
4
<Save as>
•
This button allows you to save the contents of the Buffer Window to
a file.
It is possible to specify the following properties for the file:
•
File type (HEX / Binary)
•
File Start and End Address
5
<Erase>
•
This button erases the entire contents of the Buffer Window.
•
All locations are set to the value 0xFF.
6
<Fill>
•
This button allows you to fill a specified area of the Buffer Window
with a specified value.
7
Calc CRC
•
This button calculates the CRC Checksum of the specified range of
the Buffer Window.