FS2003 ISP
Programmer - User Guide V1.07 – 1
st
September 2007
39
3.4 Programmer Operating Modes
The FS2003 programmer can be controlled in various different ways as detailed in the table below:
# Programmer
Mode
Connect
to PC
COM
Port
Control Method
/ Software
Upgrade
License
Required
Functional description
Refer
to
section
1 Development
Mode
Yes
EQTools - EDS
Standard
Feature
In this mode, the programmer
is controlled by EQTools -
Equinox Development Suite
(EDS). EDS allows you to
read/write the target device
FLASH / EEPROM / FUSE /
LOCK bits interactively under
PC control without uploading
a ‘Programming Project’ to
the programmer.
3.5
2 Standalone
Mode
No None
Standard
Feature
In this mode, the programmer
is not connected to a PC and
can program a single
‘Programming Project’ into
the Target Device when the
<YES> key is pressed. (A
valid project must have been
previously uploaded to the
programmer using EQTools –
Upload Wizard.)
3.6
3 Script
Mode
Yes
EQTools – Script
Debugger
or
ISP-PRO
Upgrade
Required
In this mode, the programmer
is controlled from a
‘Programming Script’ running
within either the EQTools or
ISP-PRO applications on a
PC.
3.8
4 ConsoleEDS
Yes ConsoleEDS Upgrade
Required
In this mode, the programmer
is controlled via the
ConsoleEDS utility which
allows control via simple
Command Line commands
and arguments.
See
App
Note
AN111