SC-T7000 series/SC-T5000 series/SC-T3000 series
Revision B
TROUBLE SHOOTING
Remedies for Service Call Error
57
Confidential
Dxxy
Debugging
Service call for FW
debugging
This error is intended to be used in the product
development stage. It is supposed to not occur to
marketed products, but may occur due to an
unexpected cause such as external noises.
Turn the power off and then turn it back on. Does the
printer recover from the error? (No repair work is
needed unless the error occurs again.)
1. Re-install the firmware.
(Page
229)
2. Replace the MAIN BOARD.
(See P.111)
Fxxx
CPU
CPU related service call There is something wrong with the firmware.
Is the firmware installed correct one for the printer?
1. Re-install the firmware.
(Page
229)
2. Replace the MAIN BOARD.
(See P.111)
1620
Pressure motor
Pressurizing
initialization error
The initialization process did not complete within a
predetermined time period.
1. Is there any abnormal load applied to the pressure
unit?
2. Is there any disconnected connectors or damaged
cables?
1. Replace the pressure unit (IC
HOLDER).
(See P.148)
2. If the error still occurs, replace
the MAIN BOARD.
(See
P.111)
1621
Pressure motor
Pressurizing/Suction
switching error
The pressurizing and suction processes did not
complete within a predetermined time period.
1. Is there any abnormal load applied to the pressure
unit?
2. Is there any disconnected connectors or damaged
cables?
1. Replace the pressure unit (IC
HOLDER).
(See P.148)
2. If the error still occurs, replace
the MAIN BOARD.
(See
P.111)
1622
Pressure motor
Operating time-out
error
The switching operation did not complete within a
predetermined time period.
1. Is there any abnormal load applied to the pressure
unit?
2. Is there any disconnected connectors or damaged
cables?
1. Replace the pressure unit (IC
HOLDER).
(See P.148)
2. If the error still occurs, replace
the MAIN BOARD.
(See
P.111)
1623
Pressure motor
Continuous revolution
error
The control terminal (Vre terminal) of the pressure
motor driver has shorted out.
1. Is the pressure motor driver on the MAIN BOARD
damaged?
2. Is there any foreign materials around the pressure
motor driver?
1. Remove the foreign materials.
2. If the error still occurs, replace
the MAIN BOARD.
(See
P.111)
Table 2-2. Service Call Error
Code
Category
Error Name
Cause
Check Item
Remedy
Summary of Contents for SC-T3000
Page 10: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 39: ...Confidential C H A P T E R 2 TROUBLESHOOTING ...
Page 66: ...Confidential C H A P T E R 3 DISASSEMBLY ASSEMBLY ...
Page 197: ...Confidential C H A P T E R 4 ADJUSTMENT ...
Page 280: ...Confidential C H A P T E R 5 MAINTENANCE ...