<Adjustment>
8. Move the CR UNIT to the left end.
9. Remove the CR COVER.
(P. 122)
10. Remove the following two plate.
Figure 4-35. Removing the plate
11. Loosen the PG adjustment screws that secure the PG adjustment levers.
12. Move the PG adjustment levers up and down to change the gap (PG).
If “2.8 no-go” is NG: Lower the lever
If “2.5 go” is NG: Raise the lever
13. Adjust all the measurement points to become within the standard.
14. Measure all the points again after adjustment to confirm all of them are within the
standard.
15. Attach the removed parts.
16. Turn the printer OFF to finish the adjustment.
Figure 4-36. PG Adjustment Levers and PG Adjustment Screws