SC-T7000 series/SC-T5000 series/SC-T3000 series
Revision B
ADJUSTMENT
CR Related Adjustments
239
Confidential
4.10.4 CR Scale Check
EXECUTION MODE
Normal mode
PROCEDURE
1. Turn the printer ON.
2. Start the Service Program and select
CR Scale Check
.
3. Click
[Run]
.
The CR UNIT moves left and right five times, and then the CR ENCODER starts
to read the scale.
The result is OK: Go to
Step 5
The result is NG: Go to
Step 4
Figure 4-22. [CR Scale Check] Screen
4. Since the CR SCALE is not scanned correctly, clean the scale using ethanol. If the
scale still cannot be read properly, replace the CR ENCODER
(P. 138)
or the CR
SCALE
(P. 135)
. After replacing the part, return to
Step 3
and check again.
5. Click
[Finish]
.
6. Turn the printer OFF to finish the adjustment.
Figure 4-23. CR Encoder and Scale Check
CR ENCODER
CR SCALE