• Operation
• Outside HP
The printer starts to perform paper
ejection operation at power-on causing
an error indication.
PF Motor
1. Check if the PF Motor Connector Cable is connected to
J9 on the Main Board.
1. Connect the PF Motor Connector Cable to J9
on the Main Board.
2. Check if the coil resistance of the PF Motor is about 6.1
Ω
by using tester
.
2. Replace the PF Motor with a new one.
3. Check if the PF Motor Connector Cable is not damaged.
3. Replace the PF Motor with a new one.
• Operation
•
–
When a top of a paper at the correct
timing during the paper loading
sequence, the paper is ejected
immediately without setting the paper
setting position for printing. But, in this
time, next paper is loaded to the PE
Sensor Lever.
ASF Unit
1. Check if the Paper Return Plate operates correctly in the
paper loading sequence.
1. Set the Torsion Spring 29.1 between the ASF
Frame and the Paper Return Plate.
Table 3-8. Check point for the paper jam error according to each phenomenon
Occurrence
timing
CR position
Detailed phenomenon
Defective
unit/part name
Check point
Remedy
PF Motor
Connector Cable
J9
Paper Return Plate
Torsion Spring 29.1
Summary of Contents for ME100
Page 1: ...EPSON StylusCX1500 ME100 Scanner Printer Copier SEOT04 006 SERVICE MANUAL ...
Page 8: ...C H A P T E R PRODUCTDESCRIPTION ...
Page 29: ...C H A P T E R OPERATINGPRINCIPLES ...
Page 47: ...C H A P T E R TROUBLESHOOTING ...
Page 72: ...C H A P T E R DISASSEMBLYANDASSEMBLY ...
Page 110: ...C H A P T E R ADJUSTMENT ...
Page 115: ...C H A P T E R MAINTENANCE ...
Page 121: ...C H A P T E R APPENDIX ...