EPSON Stylus CX1500/ME100
Revision A
TROUBLESHOOTING
Troubleshooting
52
3.3 Troubleshooting
You can identify the troubles by using the checklist in this section after confirming the LED indication on the SPC. If you connect the SPC to your PC and see an error message on
the STM3, you can short the total repair time. And, when you find out the defective parts, replace them by referring the Chapter 4 “Disassembly”. The following tables describe the
error check points.
Table 3-4. Check point for the communication error according to each phenomenon
Occurrence
timing
CR position
Detailed phenomenon
Defective
unit/part name
Check point
Remedy
• Power on
• Anywhere
When turning on the power, the SPC
does not operate at all.
Panel Unit
1. Check if the Panel Connector Cable is not damaged.
1. Replace the Panel Board with a new one.
2. Check if the Panel Board is not damaged.
2. Replace the Panel Board with a new one.
Panel Connector Cable
Panel Board
Summary of Contents for ME100