EPSON Stylus CX1500/ME100
Revision A
DISASSEMBLY AND ASSEMBLY
Disassembly
91
V
External View (2)
Figure 4-24. ASF Unit Removal (2)
3.
Remove Torsion Spring 29.1 from ASF Frame and Paper Return Plate by
using tweezers.
4.
Remove the hinge of Paper Return Plate by using tweezers, and then remove
Paper Return Plate.
Paper Return Plate
Torsion Spring 29.1
Rear View
Rear View
Hinge
Confirm that Paper Return Plate operates smoothly.
A D J U S T M E N T
R E Q U I R E D
When having removed or replaced ASF Unit, implement the
following adjustment. (Refer to Chapter 5 “ADJUSTMENT”)
T
Top margin adjustment